Numbers below are taken from the current datasheets at electrical rating. Where a value differs between formats it is shown per format — nothing here is rounded up.
| Parameter | 182R-66 · 635 W | 210-66 · 730 W | 210R-78 · 740 W |
|---|---|---|---|
| Max power (Pmax) | 600–635 W | 700–730 W | 715–740 W |
| Power steps | 8 bins, 5 W | 7 bins, 5 W | 6 bins, 5 W |
| Module efficiency | 23.50 % | 23.50 % | 23.00 % |
| Open circuit voltage Voc | 50.60 V | 49.80 V | 58.21 V |
| Short circuit current Isc | 15.95 A | 18.56 A | 16.19 A |
| Voltage at Pmax | 42.30 V | 41.70 V | 49.33 V |
| Current at Pmax Impp | 15.02 A | 17.52 A | 15.00 A |
| Isc with +10 % bifacial gain | 17.53 A | 20.42 A | 17.80 A |
| Pmax temperature coefficient | −0.29 %/°C | −0.30 %/°C | −0.29 %/°C |
| Voc temperature coefficient | −0.24 %/°C | −0.25 %/°C | −0.25 %/°C |
| NMOT | 45 ± 2 °C | 44 ± 2 °C | 44 ± 2 °C |
| Max system voltage | 1500 V DC | 1500 V DC | 1500 V DC |
| Series fuse rating | 30 A | 30 A | 35 A |
| Dimensions | 2382 × 1134 × 30 mm | 2384 × 1303 × 33 mm | 2465 × 1303 × 33 mm |
| Area | 2.701 m² | 3.106 m² | 3.212 m² |
| Weight | 33.5 kg | 37.5 kg | 38.5 kg |
| Cell type / count | 182 × 105 mm · 132 (6×11+6×11) | 210 × 105 mm · 132 (6×11+6×11) | 210 × 91 mm · 156 (6×13+6×13) |
| Glass | 2.0 mm anti-reflective tempered front + 2.0 mm tempered rear (double glass)all three formats | ||
| Frame / junction box | Anodised aluminium alloy · IP68 junction box, 1500 V DC · MC4-compatible connectorsall three formats | ||
| Operating temperature | −40 °C to +85 °Call three formats | ||
| Packing | 37 pcs/box × 20 boxes · 1270 kg gross/box | 33 pcs/box × 22 boxes · 1280 kg gross/box | 33 pcs/box × 22 boxes · 1327 kg gross/box |
| Load per 40 ft HQ | 740 pcs · ≈470 kW · 25.4 t | 726 pcs · ≈530 kW · 28.2 t | 726 pcs · ≈537 kW · 29.2 t |
High-current modules quietly break designs. The number that matters is the inverter's maximum DC input current per MPPT, checked against module Isc — not Impp — multiplied by the number of parallel strings. Bifacial gain adds roughly another 10% on top. We check this against your inverter datasheet before quoting, not after delivery.
| Format | Isc at STC | Isc + 10 % bifacial | One string | Two strings in parallel | Minimum per-MPPT rating |
|---|---|---|---|---|---|
| 182R-66 | 15.95 A | 17.53 A | 17.5 A | 35.1 A | 36 A if double-stringed |
| 210R-78 | 16.19 A | 17.80 A | 17.8 A | 35.6 A | 36 A if double-stringed |
| 210-66 | 18.56 A | 20.42 A | 20.4 A | 40.8 A | 41 A if double-stringed |
210R-78 runs 58.21 V per module (Voc coefficient −0.25 %/°C). On a 1100 V system corrected to −10 °C the module sits at 63.3 V, which caps the string at 17. At −20 °C it is 16. Most Gulf and West African sites design to −5 to 0 °C and can take 17; if your design ambient is lower, tell us and we will run it again rather than guess. Tell us your site's design ambient temperature and we will send the string length, not a guess.
The formats pass 2400 Pa wind and 5400 Pa snow under IEC 61215. Those are test-pass values, not design allowances. On large formats in snow load above 1.5 kN/m², have a structural engineer verify purlin spacing — we will supply the load data sheet for it.
33.5 kg is a two-person carry. 37.5–38.5 kg on a 3.1–3.2 m² panel needs suction lifters on rooftops. Larger formats also carry a higher transit breakage rate, so we cap it contractually at ≤0.3% with free replacement of the excess.